在数据库恢复中,ORA-600 2662我想是很多人都非常熟悉的错误,下文是对于该错误的一些解释
ORA-600 2662解释说明
ERROR:
Format: ORA-600 [2662] [a] [b] {c} [d] [e]
VERSIONS:
versions 6.0 to 12.1
DESCRIPTION:
A data block SCN is ahead of the current SCN.
The ORA-600 [2662] occurs when an SCN is compared to the dependent SCN
stored in a UGA variable.
If the SCN is less than the dependent SCN then we signal the ORA-600 [2662]
internal error.
ARGUMENTS:
Arg [a] Current SCN WRAP
Arg [b] Current SCN BASE
Arg {c} dependent SCN WRAP
Arg [d] dependent SCN BASE
Arg [e] Where present this is the DBA where the dependent SCN came from.
出现ORA-600 2662可能的原因
(1) doing an open resetlogs with _ALLOW_RESETLOGS_CORRUPTION enabled
(2) a hardware problem, like a faulty controller, resulting in a failed
write to the control file or the redo logs
(3) restoring parts of the database from backup and not doing the
appropriate recovery
(4) restoring a control file and not doing a RECOVER DATABASE USING BACKUP
CONTROLFILE
(5) having _DISABLE_LOGGING set during crash recovery
(6) problems with the DLM in a parallel server environment
(7) a bug
ORA-600 2662解决方法
(1) if the SCNs in the error are very close, attempting a startup several
times will bump up the dscn every time we open the database even if
open fails. The database will open when dscn=scn.
(2)You can bump the SCN either on open or while the database is open
using Event:ADJUST_SCN
Be aware that you should rebuild the database if you use this
option.